Main Menu
105
Unit Setting
Container ID:
Sets the container identification number. Enter up to 11 characters (numbers or letters).
In-Range Temperature limit:
Sets the temperature value for the controller’s In-range LED and datalogger
functions (factory default = 1.5 C [2.7 F]). Enter a value from 0.5 to 5.0 C (0.9 to 8.9 F).
Padlock Option :
Select ON/OFF.
Unit Configuration (Configuration Depends on Unit)
20 FT. Unit:
This tells the controller that this is the option chosen.
Heater Element Type:
Select from Extended Capacity and Normal Capacity
USDA Option:
When USDA sensor is mounted you can change the setting here.
Auto Configuration:
View
display on or off value
(factory default = off). Set value to on to automatically
configure unit to installed components.
Sensor
Calibrate Probes:
Used to calibrate sensor probes.
Options
AFAM Module:
This turns on the AVL option. Select from None, AVL, AFAM, and AFAM+. Selecting
AFAM+ also turns Optiset ON.
Humidity Sensor:
When humidity sensor is mounted you can change the setting here.
Suction Pressure Sensor:
When suction pressure sensor is mounted you can change the setting here.
Discharge Pressure Sensor:
When discharge sensor is mounted/changed you can change the setting here.
AVL Sensor :
Again if AVL sensor is mounted you can change the setting here.
MTS Feature:
Select ON/OFF.
CT Feature:
Select ON/OFF.
Smart PYI Trial:
Select ON/OFF.
Miscellaneous Settings
DATE/TIME .
Sets the controller time and date.
Contrast .
Used to adjust Screen Display contrast.
Firmware Version.
Displays Controller Software/Application Revision, Bootloader Revision, Power
Module Revision, Serial Number, and Option File Revision.
Controller ID .
View and Edit Controller ID.
Power Module ID .
An 8 digit alpha / numeric power module number - found on the power module.
Unit Serial ID .
Is the TK serial number of the unit itself. This is a ten digit alpha / numeric entry found
under the UNIT Serial Number on the Serial Plate on the unit.
Unit ID :
A 12 digit alpha / numeric unit serial number (old system).
NOTE: MAGNUM units without a container number beginning with MAE, MSF or MWC must be set
for USDA temperature sensing. See “USDA Type” above.
4. To set a new Configuration screen value:
a. Press the
F4 E
NTER
KEY
with cursor in the desired menu line.
b. Press the
F2
OR
F3 U
P
/D
OWN
U
P
/D
OWN
keys to scroll the value to the desired setting.
Summary of Contents for 098203
Page 2: ......
Page 3: ...MAGNUM TK 60275 4 MM Rev 3 08 15 Copyright 2012 Ingersoll Rand EMEIA Printed in Ireland...
Page 193: ...Refrigeration Maintenance 191 Figure 163 Filter Drier...
Page 200: ...Refrigeration Maintenance 198 Figure 169 Receiver Tank Figure 170 Water Cooled Condenser Tank...
Page 257: ...255 Schematic Diagram RELEASED 19 Sep 2013...
Page 258: ...256 Wiring Diagram Page 1 of 2 RELEASED 19 Sep 2013...
Page 259: ...257 Wiring Diagram Page 2 of 2 RELEASED 19 Sep 2013...
Page 263: ......