Smart PTI
Use to enable ON or Disable OFF the Smart PTI surveillance. Smart PTI automatically monitors
individual component performance during normal reefer operation and during defrost cycles. When a
Smart PTI cycle is completed, the results are stored in the controller memory and a <SMART-PTI Pass>
flag is logged. A timer is then automatically started to determine next cycle start. A menu point and a
checkmark symbol provide visual status of the last passed Smart PTI on the controller display. All checks
are performed during normal reefer operation. There is no need for additional off-line operations and
unnecessary energy consumption. The Smart PTI results logging can be requested anytime.
Figure 59: Smart PTI
Alarm List
Display show either NO ALARMS or the newest ALARM. See to “Alarms/Warnings Menu” on page 99
for more information.
Figure 60: No Alarms or Newest Alarm