Diagnosis: Troubleshooting, Warnings and Alarm Codes
250
128
Supply Air Temperature Probe Error
• Occurs during pretrip (PTI) test and probe test only.
• After ventilation with the evaporator fans.
• If the supply and return air temperature sensor
differs more than 1,5C and the return air
temperature is within 1,5C of evaporator coil
temperature.
• If evaporator coil temperature sensor is failing, if the
supply and return air temperature sensors differs
more than 1,5C. Both alarm 129 and 128 will be set.
• Indicates:
• Failing sensors.
• Misplaced sensors.
• Failing controller.
• Use the DATA menu to detect the failing
sensor.
• Replace sensors.
• Use the tester to determine the problem.
129
Return Air Temperature Probe Error
• Occurs during pretrip (PTI) test and probe test only.
• After ventilation with the evaporator fans.
• If the supply and return air temperature sensor
differs more than 1,5C and the supply air
temperature is within 1,5C of evaporator coil
temperature.
• If evaporator coil temperature sensor is failing, if the
supply and return air temperature sensors differs
more than 1,5C. Both alarm 129 and 128 will be set.
• Indicates:
• Failing sensors.
• Misplaced sensors.
• Failing controller.
• Use the DATA menu to detect the failing
sensor.
• Replace sensors.
• Use the tester to determine the problem.
130
Evaporator Coil Temperature Probe Error
• Occurs during pretrip (PTI) test and probe test only.
• After ventilation with the evaporator fans.
• If the evaporator coil temperature differs more than
1,5C from the mean value of supply and return air
temperature.
• Indicates:
• Failing sensors.
• Misplaced sensors.
• Failing controller.
• Use the DATA menu to detect the failing
sensor.
• Replace sensors.
• Use the tester to determine the problem.
Alarm Codes, Descriptions and Corrective Actions (Continued)
Code
Description
Corrective Action
Summary of Contents for 098203
Page 2: ......
Page 3: ...MAGNUM TK 60275 4 MM Rev 3 08 15 Copyright 2012 Ingersoll Rand EMEIA Printed in Ireland...
Page 193: ...Refrigeration Maintenance 191 Figure 163 Filter Drier...
Page 200: ...Refrigeration Maintenance 198 Figure 169 Receiver Tank Figure 170 Water Cooled Condenser Tank...
Page 257: ...255 Schematic Diagram RELEASED 19 Sep 2013...
Page 258: ...256 Wiring Diagram Page 1 of 2 RELEASED 19 Sep 2013...
Page 259: ...257 Wiring Diagram Page 2 of 2 RELEASED 19 Sep 2013...
Page 263: ......