16
Specifications
System Net Cooling Capacity— Full Cool
Evaporator Airflow Specifications
Model — Air Cooled
Condensing*
Return air to
evaporator coil
inlet
460/230V, 3 Phase, 60 Hz Power
Net Cooling Capacity
Power
Consump
60 Hz
Capacity
B/hr
60 Hz
Capacity
kW
60 Hz Power
kW
21.1 C (70 F)
56,700
16.603
11.55
1.7 C (35 F)
40, 945
11.990
11.03
-17.8 C (0 F)
24,785
7.258
7.57
-29 C (-20 F)
17, 215
5,041
6.6
-35 C (-31 F)
14,000
4.104
6.03
*System net cooling capacity with a 38 C (100 F) ambient air
temperature and R-404A.
System Net Heating Capacity*
460/230V, 3 Phase, 60 Hz Power
380/190V, 3 Phase, 50 Hz Power
Heating Capacity
Heating Capacity
Watts
Kcal/hr
BTU/hr
Watts
Kcal/hr
BTU/hr
normal
5,250
4,515
17,914
3,900
3,353
13,300
extended
7,250
6,234
24,738
5,550
4,772
18,937
*System net heating capacity includes electric resistance rods and fan heat.
External Static
Pressure (water
column)
460/230V, 3 Phase, 60 Hz Power
380/190V, 3 Phase, 50 Hz Power
High Speed
Low Speed
High Speed
Low Speed
m
3
/hr
ft
3
/min
m
3
/hr
ft
3
/min
m
3
/hr
ft
3
/min
m
3
/hr
ft
3
/min
0 mm (0 in.)
6,560
3,860
3,170
1,865
5,480
3,225
2,710
1,595
10 mm (0.4 in.)
5,820
3,425
1,770
1,040
4,530
2,665
930
545
20 mm (0.8 in.)
5,000
2,940
—
—
3,750
2,205
—
—
30 mm (1.2 in.)
4,430
2,610
—
—
2,930
1,725
—
—
40 mm (1.6 in.)
3,520
2,070
—
—
1,870
1,100
—
—
Summary of Contents for 098203
Page 2: ......
Page 3: ...MAGNUM TK 60275 4 MM Rev 3 08 15 Copyright 2012 Ingersoll Rand EMEIA Printed in Ireland...
Page 193: ...Refrigeration Maintenance 191 Figure 163 Filter Drier...
Page 200: ...Refrigeration Maintenance 198 Figure 169 Receiver Tank Figure 170 Water Cooled Condenser Tank...
Page 257: ...255 Schematic Diagram RELEASED 19 Sep 2013...
Page 258: ...256 Wiring Diagram Page 1 of 2 RELEASED 19 Sep 2013...
Page 259: ...257 Wiring Diagram Page 2 of 2 RELEASED 19 Sep 2013...
Page 263: ......