109
2. Press the
F4 E
NTER
KEY
to expand this menu.
3. Press the
F2
OR
F3 U
P
/D
OWN
key to scroll through submenu until [TRIP START] appears in display.
4. Press the
F4
ENTER
KEY
to enter Trip Start function. The date and time of the last trip start appears in
the screen.
5. Press the
F4
ENTER
KEY
again to enter a new start of trip date and time in the log.
NOTE: When a PTI test is completed, the controller automatically enters a Trip Start in the log.
6. Press the
F1
key to exit the Commands menu.
Set Log Time Interval
With the
U
NIT
TURNED
O
N
Allow Unit to start and stabilize
and the Display showing the unit status
display (setpoint):
1. Press the
F4 M
ENU
key. Press the
F3
key to scroll down to the DATALOGGER Menu.
2. Press the
F4
ENTER
KEY
to access the Datalogger menu.
3. Press the
F2
OR
F3 U
P
/D
OWN
key to scroll through submenu to [SET LOG TIME INTERVAL]
4. Press the
F4
ENTER
KEY
to enter Temp Log. Display shows the current Log Time interval.
5. Press the
F4
ENTER
KEY
again with cursor in [LOG TIME] menu line to enter a new log interval.
[ARROW] appears in menu line.
6. Press the
F2
OR
F3 U
P
/D
OWN
key to increase or decrease the Log Interval.
*The logging of USDA sensors is fixed at 1 hour intervals to comply with USDA requirements. A
logging test of USDA sensors at 1 minute intervals is possible for 72 minutes. USDA data can not be
downloaded during the logging test and can only be viewed on screen. After 72 minutes, controller
returns to previous logging interval and clears USDA test data from data logger memory.
7. When the correct Log Time appears in the menu line, press and hold the
F4
ENTER
KEY
until cursor
stops flashing. The new Log Time appears in the display.
8. Press the
F1
key to exit.
Summary of Contents for 098203
Page 2: ......
Page 3: ...MAGNUM TK 60275 4 MM Rev 3 08 15 Copyright 2012 Ingersoll Rand EMEIA Printed in Ireland...
Page 193: ...Refrigeration Maintenance 191 Figure 163 Filter Drier...
Page 200: ...Refrigeration Maintenance 198 Figure 169 Receiver Tank Figure 170 Water Cooled Condenser Tank...
Page 257: ...255 Schematic Diagram RELEASED 19 Sep 2013...
Page 258: ...256 Wiring Diagram Page 1 of 2 RELEASED 19 Sep 2013...
Page 259: ...257 Wiring Diagram Page 2 of 2 RELEASED 19 Sep 2013...
Page 263: ......