Diagnosis: Troubleshooting, Warnings and Alarm Codes
245
70
O2 Sensor Error
• Occurs during pretrip (PTI) test only.
• If the sensor reading is not ready and valid within
10 minutes.
• Indicates:
• Failing sensor, not capable of heating up or
create conditions for valid reading.
• Redo the test.
• Replace sensor.
71
CO2 Sensor Error
• Occurs during pretrip (PTI) test only.
• If the sensor reading is not ready and valid within
10 minutes.
• Indicates:
• Failing sensor, not capable of heating up or
create conditions for valid reading.
• Redo the test.
• Replace sensor.
Alarm Codes, Descriptions and Corrective Actions (Continued)
Code
Description
Corrective Action