Operating Theory
141
Figure 113: Standard Display Showing CT In Process
Stopping Cold Treatment
1. Press the CT Key.
2. Scroll down to ABORT CT - PRESS >STOP< and press STOP.
Figure 114: Stopping CT
3. The Standard Display will appear and “CT In Progress” will disappear from the display.
Passed Cold Treatment – must be acknowledged
To ensure the user observe the passed display, Acknowledge CT will be displayed until it is
acknowledged by pressing the CT Key and them pressing the ACK Key.
Surveillance during cold treatment
During the CT period all USDA sensors can fail and the CT period will continue.
The fail state will be shown in the temperature log.
If all 3 probes fail the period will continue based on time only.
RMM / Refcon:
The RMM at no time during the CT is able to change any of the CT settings
The RMM interface will show the final temperature as setpoint through out the trip, even when the period
is running and another setpoint is used.
Economy mode:
Running economy mode either manually or automatically by the AVL, will automatically be set to OFF
during CT pull down and period. After the CT period ends the economy mode is reinstated (starting from
warm up phase).
Summary of Contents for 098203
Page 2: ......
Page 3: ...MAGNUM TK 60275 4 MM Rev 3 08 15 Copyright 2012 Ingersoll Rand EMEIA Printed in Ireland...
Page 193: ...Refrigeration Maintenance 191 Figure 163 Filter Drier...
Page 200: ...Refrigeration Maintenance 198 Figure 169 Receiver Tank Figure 170 Water Cooled Condenser Tank...
Page 257: ...255 Schematic Diagram RELEASED 19 Sep 2013...
Page 258: ...256 Wiring Diagram Page 1 of 2 RELEASED 19 Sep 2013...
Page 259: ...257 Wiring Diagram Page 2 of 2 RELEASED 19 Sep 2013...
Page 263: ......