Main Menu
114
Starting the AFAM System
1. Press the
M
ENU
F4
key to enter the main menu. Press the
F2
or
F3
key to scroll to
Config
Menu and
press
F4
to expand the menu.
2. Press the
F2
or
F3
key to scroll to
Options
Menu and press
F4
to expand the menu.
3. Press the
F2
or
F3
key to scroll to
Controlled Atmosphere (CA)
Menu and press
F4
to enter the
menu.
4. Press the
F2
or
F3
key to select
AFAM
and Press and hold
F4
to accept the selection.
Figure 93: Controlled Atmosphere (CA) Menu
5. Press the
F1
key several times to return to the standard display.
6. Press the
M
ENU
F4
key to enter the main menu. Press the
F2
or
F3
key to scroll to
Setpoint/Control
Menu and Press
F4
to expand the menu.
7. Press the
F2
or
F3
key to scroll to [Fresh Air Vent Man] line.
8. Press the
F4
key to enter the Fresh Air Vent Man menu.
9. Press the
F2
or
F3
key to scroll between [OFF] and [AFAM].
•
[OFF]: Vent door closes and/or remains closed. AFAM Delay and AFAM Rate settings disappear.
•
[AFAM]: Controller uses enter AFAM DELAY and AFAM RATE time to adjust FAE door to user
setting.
WARNING: The vent door and motor actuator arm move immediately when the
F4
key is
pressed to turn the AFAM system to AFAM or Off. Keep hands and tools away from the air
exchange system components to prevent personal injury or unit damage.
Summary of Contents for 098203
Page 2: ......
Page 3: ...MAGNUM TK 60275 4 MM Rev 3 08 15 Copyright 2012 Ingersoll Rand EMEIA Printed in Ireland...
Page 193: ...Refrigeration Maintenance 191 Figure 163 Filter Drier...
Page 200: ...Refrigeration Maintenance 198 Figure 169 Receiver Tank Figure 170 Water Cooled Condenser Tank...
Page 257: ...255 Schematic Diagram RELEASED 19 Sep 2013...
Page 258: ...256 Wiring Diagram Page 1 of 2 RELEASED 19 Sep 2013...
Page 259: ...257 Wiring Diagram Page 2 of 2 RELEASED 19 Sep 2013...
Page 263: ......