Alarm List/Warming List
• View and write down
all alarm/warning codes.
• Press F2 key to view
the next alarm/warning code.
• Clear alarm/warning code by
correcting problem and
acknowledging the alarm.
• To acknowledge an
alarm/warning, press F4 key with
alarm/warning code in display.
ALARM LIST
WARNING LIST
CONFIGURATION
Configuration Menu
- Unit Setting
- Unit Configuration
- Sensor
- Options
- Miscellaneous
Settings
- Container ID
- In Range
Temperature Limit
- Padlock Option
- Date/Time
- Contrast
- Firmware Version
- Controller ID
- Power Module ID
- Unit Serial ID
- Unit ID
- 20 ft Unit
- Heater Element Type
- USDA Option
- Auto Configuration
Set Time/Date
• Press F4 key to select
this menu.
• Press F4 key again to
edit.
• Press F2 or F3 key to
increase or decrease a
digit
• Press F4 to move to
the next digit.
• Press and hold F4 key
to save until you are
returned to the main
screen
To Select an option in the
Unit Configuration Menu
• Press F4 key to select
Option.
• Press F2 key to scroll
setting between settings.
• Press and hold F4 key
until you are returned to
the main screen
- AFAM Module
- Humidity Sensor
- Suction Pressure Sensor
- Discharge Pressure Sensor
- AVL Sensor
- MTS Feature
- CT Feature
- Smart PTI Trial
To Calibrate Probes
Press F3 key to Release.
Press F4 key to Calibrate.
- Calibrate Probes
PTI Test Menu
• Press F2 or F3 key to
scroll through tests.
• Press F4 key to start test.
- No Action
- Manual Function Test
- Function Test
- Humidity Sensor PTI
- Chilled PTI
- Brief PTI
- PTI
- Probe Test
- Show PTI Info
Setpoint/Control Menu
- Cold Treatment
- Multiple Temp. Set
- OPTISET
- Temp. Setp.
- Controlling Mode
- Pull Down Selection
- Watercool
- Hum. Control
- Hum. Setpoint
- AVL Open Valve
- Defrost Trm. Temp
- Defrost Interval
- Spec. 24-48h Defrost
- USDA Trip
- AFAM Mode
- AFAM Delay
Enter a Temperature or
Humidity Setpoint
• Press F4 key to select
this menu.
• Press F2 or F3 key to
increase or decrease
setting
• Press and hold F4 key
until you are returned
to the main screen
Activate Humidity Contol
• Press F4 key.
• Press F2 key to scroll
setting between OFF
and ON.
• Press and hold F4 key
until you are returned to
the main screen
DATA
SETPOINT/
CONTROL
RMM Status
- RMM Status Display shows
current status:
- Version
- Map Telegrams Received
- Minutes since last Poll
Datalogger Menu
- Inspect Log
- Inspect Event Log
-Inspect Temperature Log
- Inspect Smart Log
- Trip Start
- Set Log Time Interval
Datalogger Submenu
- Inspect log: Press F4 key
to view next screen. Press
F2 or F3 key to scroll
through all logs.
- Set Log Time Interval:
Press F3 key to scroll
through log interval list.
Press and hold F4 key
until cursor stops
flashing.
DATALOGGER
STATES
Manual Function Test Submenu
- Phase Direction
- Heater
- Compressor
- Evaporator Fan Low
- Evaporator Fan High
- Condenser Fan
- Economizer Valve
- Digital Valve
- 3-Relay-Output C
- 3-Relay-Output D
- 3-Relay-Output I
• Press F2 or F3 key to scroll through tests.
• Press F4 key to toggle between ON and OFF
(or Forward and Reverse).
• More than one component can be turned ON
at a time to perform a functional test of the unit.
MAIN MENU
CONTROLLER MENU GUIDE
NOTE: All screens are NOT present on all units. The screen
that display on the controller are determined by the
Controller Software setting and the options installed on the
unit.
NOTE: When a function key (F1, F3, F3 or F4) is pressed,
the screen remains at that level until another function key is
pressed.
To Enter a Controller Menu or Use Special Function Key
:
• Press Alarm Key to Quickly view/Acknowledge Alarms (F1).
• Press C/F key to view alternate temperature scale in LED
display (F2).
• Press SETPOINT Key to Quickly change Setpoint (F3)
• Press MENU Key to view the main menu (F4)
• Press DEFROST key to initiate a manual defrost. Evaporator
coil temperature must be below 10C (50F) (*).
• Press PTI key to enter the PreTrip menu.
To Enter a Submenu, a Command or a New Value in a
Text Screen
:
• Press F4 key.
To Scroll in a Menu or a Text Line
:
• Press F2 key to scroll up or backward.
• Press F3 key to scroll down or forward.
To Exit a Menu or Text Line
:
• Press F1 key.
To Lock a LCD Data Screen Display
:
Maximum display time is 30 minutes for data screens and 100
minutes for manual tests. Press F1 key to exit display.
•
F1
Alarms Menu
•
F2
C TO F
•
F3
SETPOINT
•
F4
MENU
- Voltage
- Current
- Curr. Ph. 1
- Curr. Ph. 2
- Curr. Ph. 3
- Frequency
- Modulation
- AVL Position
- Radiator
- Suct. Press
- Disch. Press
- Curr. Ph. 3
- CO2
Fresh Air Ex
-Battery Voltage
- Battery c. current
- Bat, Temp
- CO2
- O2
- pt 1000 spare
- Supply LH
- Supply RH
- Return
- Evaporator
- Condensor
Data Menu
- Compressor
- Ambient
- Humidity
- USDA 1, 2, 3
- Cargo
• Offline
• Zombie
• Online
States Menu
- Cold Treatment
- Multiple Temp. Set
- PTI
- Input - Output
- RMM
- AFAM Rate
- C02 Max.
- 02 Min.
- Smart PTI
- RMM+
- Defrost
- Water Cooled Cond.
- Runtime Counters
- Expansion Module 1
- Expansion Module 2
- Misc. Feature
- End Pulldown Phase
- Go To Idle Menu
- External Bus Devices
DERFOST
Defrost Menu
- No Action
- Start Defrost
- Show Defrost Info
• Press F2 or F3 key to scroll through selections.
• Press F4 key to accept.
• Turn unit Off with ON/OFF key to stop Defrost before it is completed.
Summary of Contents for 098203
Page 2: ......
Page 3: ...MAGNUM TK 60275 4 MM Rev 3 08 15 Copyright 2012 Ingersoll Rand EMEIA Printed in Ireland...
Page 193: ...Refrigeration Maintenance 191 Figure 163 Filter Drier...
Page 200: ...Refrigeration Maintenance 198 Figure 169 Receiver Tank Figure 170 Water Cooled Condenser Tank...
Page 257: ...255 Schematic Diagram RELEASED 19 Sep 2013...
Page 258: ...256 Wiring Diagram Page 1 of 2 RELEASED 19 Sep 2013...
Page 259: ...257 Wiring Diagram Page 2 of 2 RELEASED 19 Sep 2013...
Page 263: ......