MOVU OVC,loc16
6-222
MOVU OVC,loc16
Load Overflow Counter With Unsigned Value
SYNTAX OPTIONS
OPCODE
OBJMODE
RPT
CYC
MOVU OVC,loc16
0101 0110 0110 0010
0000 0000 LLLL LLLL
1
−
1
Operands
OVC
6-bit overflow counter
Description
Load the overflow counter (OVC) with the lower 6 bits of the location pointed
to by the “loc16” addressing mode:
OVC = [loc16(5:0)]
Flags and
Modes
OVC
The 6-bit overflow counter is modified.
Repeat
This instruction is not repeatable. If this instruction follows the RPT
instruction, it resets the repeat counter (RPTC) and executes only once.
Example
; Save and restore contents of ACC and OVC bits:
MOVU *SP++,OVC
; Save OVC on stack
MOV *SP++,AL
; Save AL on stack
MOV *SP++,AH
; Save AH on stack
.
.
.
.
MOV AH,*−−SP
; Restore AH from stack
MOV AL,*−−SP
; Restore AL from stack
MOVU OVC,*−−SP
; Restore OVC from stack