MagicQ User Manual
285 / 348
• PanJit TouchSet
• eTurboTouch
• Gunze AHL61
• DMC TSC-10/25
• IRTOUCHSYSTEMS/UNITOP
• IdealTEK URTC1000
• General Touch
• GoTop Super_Q2/GogoPen/PenPower tablets
• JASTEC USB touch controller/DigiTech DTR-02U
• Zytronic capacitive touchscreen
• NEXIO/iNexio
MagicQ Compact consoles do not support multi touch touch screens.
MagicQ will show any detected touch screens in Setup, View System, View Monitors.
41.6.3
Configuring an external Touch Screen
To configure an external serial touch screen:
• In Setup, Vew Settings, Ports set Serial Remote Protocol to one of Ideal Touch, Pro Touch, A1 Touch, Elo Touch.
• In Setup, Vew Settings, Ports set Serial baud rate, parity, data bits, stops buts. If in doubt set baud rate to 9600, data to 8 bits,
stop bits to 1 and no parity.
• Select the Serial Touch Monitor to the monitor the serial touch is associated with.
• Press ALT + CNTRL + SHIFT together to enter board test mode. Moving a finger around the edge of the screen should report
incrasing/decreasing X,Y values in the Status Window.
• Exit board test mode (ALT + CNTRL + SHIFT).
• Go to Setup, View Settings and select Calibrate Touch. Press 1 to confirm.
• Now press the X on the external touch screen in the four different positions as requested. Do not press on any other monitors
except the one being calibrated.
To configure an external USB touch screen:
• Set up the Touch Type in Setup, View Settings, Monitors. Start with Normal or eGalax.
• If a touch screen is detected then it will show up in the Touch Status field.
• Press ALT + CNTRL + SHIFT together to enter board test mode. Moving a finger around the edge of the screen should report
incrasing/decreasing X,Y values in the Status Window.
• Exit board test mode (ALT + CNTRL + SHIFT).
• Go to Setup, View Settings and select Calibrate Touch. Press 1 to confirm.
• Now press the X on the external touch screen in the four different positions as requested. Do not press on any other monitors
except the one being calibrated.
If the Touch Screen shows a status but does not give consistent values in Board Test then try a different Touch Type.
If the Touch Screen shows consistent values in Board Test but does not respond correctly then recalibrate the touch screen.