MagicQ User Manual
273 / 348
40.3.3
Auto Patch
MagicQ supports the WYSIWYG Auto Patch protocol. Selecting Auto Patch on WYSIWYG transfers the patch to MagicQ. To
transfer a new show to MagicQ first erase the show in MagicQ and then select Auto Patch, Send Patch in WYSIWYG.
MagicQ identifies the fixtures in WYSIWYG and maps the names to the MagicQ fixtures using a mapping table. If MagicQ can
not identify a fixture it will not be able to auto patch a fixture. The mapping between MagicQ personality and WYSIWYG fixture
is specified in the MagicQ personality. Not all the different fixture modes are supported by both WYSIWYG and MagicQ.
When performing an Auto Patch, MagicQ will report any fixtures that it can not match. To fix a personality, edit the head in the
Head Editor, setting the correct WYSIWYG name. If the WYSIWYG name is empty then pressing ENTER will fill in with the
name received from WYSIWYG for the last mismatch.
40.3.4
Auto Focus
MagicQ supports the WYSIWYG Auto Focus protocol. If you turn Auto Focus on for the ChamSys port in the Device Manager
on WYSIWYG then changes made in WYSIWYG design mode will be relayed to the programmer in the console.
40.3.5
Troubleshooting
Problem: WYSIWYG does not receive any data.
Solution: Check that you have installed the MagicQ WYSIWYG driver on the WYSIWYG PC. Check that the connection is
connected in WYSIWYG device manager. Check that you have configured the correct MagicQ universes to use WYSIWYG as
their Vsualiser.
Problem: WYSIWYG will not connect on the same PC as MagicQ.
Solution: Check that you have configured the Visualiser to be WYSIWYG (same PC) in the Setup Window.
Problem: WYSIWYG will not connect between two separate PCs.
Solution: Check that the network ports on the two PCs are configured to the same IP subnet, that they are enabled, and that you
have configured MagicQ to use the correct network port (Setup, View Settings, IP address).
Problem: WYSIWYG connects but no control of the lamps
Solution: Check the MagicQ Universe in WYSIWYG is bound to the MagicQ device.
40.4
ESP Vision
ESP vision supports ArtNet control. Simply set the required universes to Out Type of ArtNet and enable them. The Visualiser
field should be set to “None”.