Recording Synchronization
5-26
R X
L A N
S ER IA L NO .
MA D E I N J A PA N
Settings and Recording Operations
Use the LX Navi menu of each master/slave unit for the amp and input range parameter settings, the sampling
frequency, and so on. Make sure to use the same sampling frequency and the recording media for the units to
be recording synchronized.
Use the LX Navi of the master unit to start and stop recording synchronization, the slave units follows start/stop
operation of the master unit.
Connecting Recording Synchronization Cables and Turning on Power
1.
Connect among the LX units to be synchronized by using the synchronization cables.
The <SYNCHRO IN> connector and the <SYNCHRO OUT> connector are used for recording synchronization.
Connect the <SYNCHRO OUT> connector of the first unit to the <SYNCHRO IN> connector of the second unit. If you have
the third unit, connect the <SYNCHRO OUT> connector of the second unit to the <SYNCHRO IN> connector of the third unit.
Then connect another unit accordingly.
2.
In case of the IEEE1394 interface models, use the IEEE1394 cables to connect among the units in daisy
chain. Connect the PC installed the LX Navi to one of the units.
In case of the Ethernet interface models, use a switching hub to connect the units and the PC installed the LX
Navi.
3.
Turn ON the powers of the LX units and then the PC.