INSTRUCTION MANUAL
18
6. THE INTRODUCTION OF THE S-80 COLLARING MACHINE
6.1. DESCRIPTION OF THE CONTROL DEVICES
6.1.1. MAIN SWITCH
The main switch of the unit is placed on the electric cabin door. The main switch can be
locked with a padlock in order to prevent unauthorized use of the machine.
The power is switched on by turning the main switch to “ON” (I) position. The power is
switched off by turning the main switch to “OFF” (O) position.
When the power is switched “ON” the machine “OFF”-button on the control panel is lit
red, and the start screen opens to the display.
6.1.2. CLAMP REMOTE CONTROL CB3
1
2
3
Clamp remote control: 1. Manual control ON-OFF, 2. Clamps close, 3. Clamps open.
The remote control is for positioning of the tube to the clamps: final clamp tightening is
done automatically when the work cycle starts. Turn machine to MANUAL from control
panel switch and activate remote control from pendant switch (1).
L
Ohere is a continuous pressure on the clamp control pneumatic line
to keep the tube from falling off the clamps when the emergency stop
is pushedE!
The continuous pressure line is marked with signal tape. This certain line is
depressurized only when the main air supply is switched off.