COLLARING MACHINE
65
S-80
8.1. CLAMPING DEVICE MAINTENANCE AND ADJUSTMENT
Adjustment of the clamping center point
The Manual Feed Table defines the clamping center Y-axis position, because the MFT
does not have an adjustment of Y-axis direction.
The adjustment is required if the
clamping device has been removed.
Instruction:
1.
Remove the posterior pneumatic cylinder (1).
2.
Open the locking screws of the toothed rack (2).
3.
Place a gauge tube to the MFT. Adjust the clamps by the adjustment screw to grab the
gauge tube. Make sure to leave a stroke margin for the clamping cylinder (theoretical
1,5mm+1,5mm).
4.
Tighten the locking screws of the toothed rack and the adjustment screw nuts.
1 2
3
Adjustment of the clamping center point
1
2
Lubricate the clamping device centering mechanism by grease nipples using a grease gun
once a month, use vaseline KLÜBER ISOFLEX TOPAS L152 (NLGI 2) or equivalent.