COLLARING MACHINE
17
S-80
5.4.2. CONNECTION TO THE COMPRESSED AIR SYSTEM
¨NOTE!
¨
The connection of the S-80 units to the compressed air system is
to be performed only by a person authorized to this effect by the employer.
The compressed air is to be connected to a pressure regulator supplied with unit. The
pressure regulator is readily assembled and fixed in the correct position. Compressed air
supply requirements: 6-9 bar (85-130 psi).
The air supply valve can be equipped with a padlock to ensure safety during maintenance
of the machine.
¨NOTE!
¨
The clamp speed must not be adjusted, the machine warranty
expires if adjusted.
Klämpin liikenopeus
Tehdasasetus! Älä säädä! Takuu päättyy.
Clamping speed
Factory setting! Warranty expires if
adjusted.
Klämhastighet
Fabriksinställning! Garantin löper ut om
den justeras.
¨NOTE!
¨
The planetary gear lock pressure has been adjusted at the
factory, do not adjust.
Planeettavaihteiston lukon paine
Planetary gear lock pressure
Planetväxel lås tryck
Bar
5.5. START-UP CHECKING
¨NOTE!
¨
Carry out the start-up checking before using the functions of the
machine- a wrong voltage may damage the machine.
Before using the machine, proceed as follows:
1. Measure the supply voltage of the machine and check if it corresponds to the voltage
and frequency indicated on the identification plate of the machine.
2. Check the air supply. Open the main valve of the machine and set the value of the
operation pressure to 6 bar (85 psi).