COLLARING MACHINE
31
S-80
6.2.2.3.1. MACHINE SETTINGS
For Supervisor or Maintenance user level.
This page has general machine settings: When the tube size changes, all of the tube
information is set here, and the machine is able to collect machining data from the
Process settings screen corresponding parameters.
1
2
3
4
5
6
7
1.
Tube parameters
1. Tube material (user defined)
2. Tube length (If an AFT option is assembled, the
length is required)
3. Tube diameter
4. Tube wall thickness
2.
Current tools
Identification number of tool in the machine
3.
Tube offset
The position of the collar can be adjusted according
to zero point of the spindle, if the collar is not on the
correct position on the tube
4.
Trimming
Finishing time: The time the trimming blade uses to
finalize the trimmed collar by rotating without feed.
5.
Clamping
Tap to choose the automatic clamping ON or OFF
6.
Other settings:
Demo mode
Tap to choose the Demo mode ON or OFF: Mainly for
testing the program without tube, runs the program
without lubrication.
7.
Other settings:
Pause mode
Tap to choose the Pause Mode ON or OFF: Mainly for
testing purposes, the “Pause Mode” runs the process
in sections. Useful for example when testing a new
tool.