COLLARING MACHINE
85
S-80
13. APPENDIX
13.1. CAPACITY TABLE
With the aid of the capacity charts on the following pages you will be able to determine
the max. wall-thickness of the tube and select the right collaring head.
Instructions for the use of the capacity charts:
1. From the horizontal black row, find the collar size you need, and from the vertical black
column the diameter of your run tube.
2. The intersection of the horizontal and vertical rows will show you the max. wall
thickness of the tube. This value is not to be exceeded.
Example: Run tubeØ12, collar Ø10:
Ø6
Ø8
Ø10
Ø12
Ø15
Ø8
0.5
0.5
Ø10
0.8
0.8
1.0
Ø12
0.8
1.0
1.0
1.0
Ø15
0.8
1.0
1.0
1.0
1.2
Ø18
0.8
1.0
1.0
1.0
1.2
Ø22
0.8
1.0
1.2
1.2
1.5
Ø25
0.8
1.0
1.2
1.2
1.5
Ø28
0.8
1.0
1.2
1.2
1.5
Ø35
0.8
1.0
1.2
1.2
1.5
•
Wall thickness 1.0 or less
¨NOTE!
¨
These tables have been established to give directive information.
We reserve ourselves the right to change the figures. For wall thicknesses
and pipe dimensions others than the ones indicated: please do contact
your T-DRILL dealer.