COLLARING MACHINE
81
S-80
Problem
Cause
Remedy
Tap “Tool fasten” on
screen:
ALARM: Tool fasten
sequence cannot be
started
Air pressure off
Check air pressure line, switch
on air pressure to the collaring
unit: press Reset on control
panel
Lifting cylinder not down (20-B1.0) Check the cylinder positions and
move to correct position using
MANUAL
Locking cylinder not in the middle
(20-B2.1)
Work piece sensor not activated
(10-B4)
Check work piece sensor, the
locking piece must activate
sensor.
Are collaring settings OK?
Check settings.
Are tool settings OK?
Check settings.
Tap “Tool release”
on screen:
ALARM: Tool
release sequence
cannot be started
Air pressure off
Check air pressure line, switch
on air pressure to the collaring
unit: press Reset on control
panel
Lifting cylinder not up (20-B1.1)
Check the cylinder positions and
move to correct position using
MANUAL
Locking cylinder not on the side
(20-B2.0)
Work piece sensor not activated
(10-B4)
Check work piece sensor, the
locking piece must activate
sensor.
Are collaring settings OK?
Check settings.
Are tool settings OK?
Check settings.