-Shenzhen Guanhong Automation Co.,Ltd.-
SZGH-CNC1000MDb Series
- 175 -
141
M78:Machine Coordinate VS Reference point 2
1
150
X_Reference Point_1(mm)
0.000
151
Y_Reference Point_1(mm)
0.000
152
Z_Reference Point_1(mm)
0.000
153
A_Reference Point_1(mm)
0.000
160
X_Reference Point_2(mm)
0.000
161
Y_Reference Point_2(mm)
0.000
162
Z_Reference Point_2(mm)
0.000
163
A_Reference Point_2(mm)
0.000
380
X_Machine Coordinate Value at initial point(ATS)(mm)
0.00
381
Y_Machine Coordinate Value at initial point(ATS)(mm)
0.00
382
Z_Machine Coordinate Value at initial point(ATS)(mm)
0.00
383
Speed in Negative Direction(ATS)(mm/min)
0.00
384
Speed in Positive Direction(ATS)(mm/min)
0.00
385
Z_Workpiece coordinate Value at surface workpiece after ATS(mm)
0.00
386
Positioning Speed(ATS)(mm/min)
0.00
387
Mode of ATS(1:Fixed point,0: Float Point)
0.00
388
Z_Min Machine Coordinate Value(mm)
0.00
389
The Gap value of Z(mm)
0.00
390
Total times of tests for automatic tool(1--5)
1
400
Axis name display configuration [xxxxx2]
1
401
Pulse output ports Configuration for Feed Axes[xxxxxxxx0]
1
501
Shift Color Display of Screen(1:No, 8:Yes)
1
601
Define Parameters for Step
602
Define Parameters for Servo
Servo
800
System inner parameter,can’t be altered.
1
900
Display User-define Dialog Box[1:No, 4:Yes]
8192
901
Homing Sequence of Axis(5bits)
1
902
System inner parameter,can’t be altered.
0
904
System inner parameter, can’t be altered.
0
910
High-Speed Input of M18/M22/M24/M28 for G31/G311
0
911
Using M18_Teach-in, M28_Record(0:No, 1:Yes)
0
912
“Reset”key reset Outputs(0:No, 1:Yes)
1
Note:P12&P39&P40 are System Inner Parameter, cannot be altered.
Explanation about Axis Parameter:
1,Type of Handwheel(0:Panel, 1:Handheld)
It sets the type of handwheel,0:Handwheel in operational panel, 1:Handwheel in handheld box.
Note: when the parameter is 1 (P1=1), CN11 is connected to handheld box; & can’t use rate of
spindle&feeding axis,only off/X/Y/Z/A &*1/*10/*100(also P1&P2=0 in Axis parameter).
3,Using Interface Switch on Panel(0: No, 1:Yes,)
It sets whether system use interface switch on operational panel. 0:No, don’t use interface
switch; 1:Yes,use interface switch.