-Shenzhen Guanhong Automation Co.,Ltd.-
SZGH-CNC1000MDb Series
- 116 -
4.3.1.3 Coolant(M08/M09)
M08:Turn on coolant
M09: Turn off coolant
Remark
PIN
Function
M08
PIN8_CN3 Plug
Turn On/Off coolant
4.3.1.4 Lubricate(M32/M33)
M32: Turn on lubrication
M33: Turn off lubrication
Remark
PIN
Function
M32
PIN9_CN3 Plug
Turn On/Off Lubrication
In Other parameter,
P4 controls the function of lubricate automatically.
P6 is set the interval time of lubrication (Unit: s);
P5 set the time of lubrication ,also holding time of output M32(Unit: 10ms).
4.3.1.5 Chuck(M10/M11)
M10/M11 are for control clamping/unclamping of chuck.
Remark PIN
Function
M10
PIN21_CN3 Plug
Control Chuck clamping
M71
PIN9_CN10 Plug
Control chuck unclamping(Spare)
M12
PIN11_CN10 Plug Detect position of clamping_chuck(spare)
M14
PIN24_CN10 Plug Detect position of unclamping_chuck(Loose)(spare)
M16
PIN12_CN10 Plug Input point for switch to control chuck(spare)
Chuck of this system control is related with parameter as follows:
In Other parameter:
P2: Type of chuck, (Inner: Chuck to center when M10; Outer: Chuck opening outward when
M10). 1 means outer, 0 means inner.
P13: Interlock between Chuck & Rotation_Spindle.0: No interlock, 1: yes.
M12: input point for detecting position of clamping of chuck;
M14: input point for detecting position of unclamping of chuck.
P20: Type of controlling signal for chuck,0: one output controlling signal for chuck; 1: two
output controlling signals for chuck.
M10:output point for controlling clamping of chuck , controlling code is M10;
M71:output point for controlling unclamping of chuck,controlling code is M11.
P22: External Switch(Foot switch) for chuck, reciprocating mode, price one time clamping
chuck; press twice time, unclamping chuck. 0: without switch ; 1: with external switch for control
chuck; input signal is M16.
P24: Holding time of output M10/M71 of chuck, unit: s. 0: mode type*.
In Axis parameter:
P40_D1: Detect position of clamping/unclamping of chuck,0:No detect, 1: yes.
Note: 1. When user-defined signals M71/M70 , M73/M72 are used for output signal of spindle chuck and
Tailstock, it can’t be used for other functions.
2. M12,M14,M1,M18,M28 are multi-function codes, only one function when using.
3. *mode type means that once valid,always valid until canceling/resetting code.