ELECTRICAL SYSTEM 9-45
NOTE:
If no air bubbles are coming up from a filler port, tap the bottom
of the electrolyte container two or three times.
Never remove the container from the battery.
• After confirming that the electrolyte has entered the battery
completely, remove the electrolyte containers from the bat-
tery. Wait for about 20 minutes.
• Insert the caps
6
into the filler holes, pressing in firmly so that
the top of the caps do not protrude above the upper surface of
the battery’s top cover.
For initial charging, use the charger specially designed for MF battery.
* Never use anything except the specified battery.
* Once the caps have been installed to the battery, do
not remove the caps.
* Do not tap the caps with a tool such as hammer
when installing them.
CORRECT
INCORRECT
* For charging the battery, make sure to use the charger specially designed for MF battery. Other-
wise, the battery may be overcharged resulting in shortened service life.
* Do not remove the cap during charging.
* Position the battery with the cap facing upward during charging.