PERIODIC MAINTENANCE 2-9
• Remove the generator cover plug
6
and valve timing inspec-
tion plug
7
.
• Turn the crankshaft counterclockwise to set the #2 (Right) cyl-
inder at TDC of compression stroke. (Align the “| R” line
A
on
the generator rotor to the mark
B
of valve timing inspection
hole and also bring the notch
C
on the left end of camshaft to
the position as shown.)
D
Intake side
• To inspect the #2 (Right) cylinder valve clearance, use a
thickness gauge between the valve stem end and adjusting
screw. If the clearance is out of specification, adjust it into the
specified range.
Valve clearance adjuster lock-nut:
10 N·m (1.0 kgf-m, 7.0 Ibf-ft)
09900-20803: Thickness gauge
09917-14910: Tappet adjust driver