Chapter 4
Troubleshooting the System
4-19
4.6.2
Troubleshooting the Power Supply Units in the
Netra CT 810 Server
When both power supply units in a Netra CT 810 server are up and running
properly, the green (
)LEDs on both power supply units is ON (note that these are
the LEDs on the power supply units themselves,
not
the LEDs on the system status
panel).
If a power supply unit fails, the amber (
) LED on the power supply unit might
light, depending on the type of failure that occurs:
■
If a
soft-fault
occurs, such as a stuck fan or a temperature warning, a notification
of the error is given; however, the amber (
) LED on the power supply unit
does not
light for a soft-fault condition. The power supply unit is still supplying
power to the system during a soft-fault condition.
■
If a
hard-fault
occurs, such as a voltage problem, a notification of the error is
given. In addition, the amber (
) LED on the power supply unit
does
light for a
hard-fault condition. The power supply unit does
not
supply power to the system
during a hard-fault condition.
If one power supply unit fails (either a soft-fault or a hard-fault), but the other
power supply unit is still functioning normally, replace the faulty power supply unit
as soon as possible. If both power supply units fail, the action to take varies
depending on which of the two types of faults occurred:
If
Then
Both power supply units go through a
soft-fault
Replace one power supply unit at a time, in
order to keep the system up and running.
One power supply unit goes through a
soft-fault
and the other power supply unit goes through
a
hard-fault
Replace the power supply unit that has a
hard-fault first, in order to keep the system
up and running.
Both power supply units go through a
hard-fault
The system is down. Replace at least one of
the power supply units to bring the system
back up again.
Summary of Contents for Netra CT 410
Page 16: ...xvi Netra CT Server Service Manual February 2007...
Page 20: ...xx Netra CT Server Service Manual February 2007...
Page 28: ......
Page 44: ...2 10 Netra CT Server Service Manual February 2007...
Page 48: ...3 4 Netra CT Server Service Manual February 2007...
Page 49: ...PART 2 Troubleshooting the System Troubleshooting the System Chapter 4...
Page 50: ......
Page 88: ......
Page 98: ...5 10 Netra CT Server Service Manual February 2007...
Page 138: ...6 40 Netra CT Server Service Manual February 2007...
Page 154: ...7 16 Netra CT Server Service Manual February 2007...
Page 176: ...8 22 Netra CT Server Service Manual February 2007...
Page 178: ......
Page 198: ...10 10 Netra CT Server Service Manual February 2007...
Page 199: ...PART 5 Illustrated Parts List Illustrated Parts List Chapter 11...
Page 200: ......
Page 208: ...11 8 Netra CT Server Service Manual February 2007...
Page 210: ......
Page 265: ...Appendix A Connector Pinouts A 55...
Page 266: ...A 56 Netra CT Server Service Manual February 2007...
Page 288: ...D 4 Netra CT Server Service Manual February 2007...
Page 296: ...Index 4 Netra CT Server Service Manual February 2007 W web sites third party xxvi...