10-4
Netra CT Server Service Manual • February 2007
7. Unlatch the disk drive handle to release it.
Push down in the direction of the arrow to release the bracket handle latch.
8. Pull the bracket handle out and swing it open.
9. Continue to pivot the disk drive bracket handle against the chassis, applying mild
pressure until the drive disconnects.
10. Slide the drive out of the chassis and place it on the electrostatic discharge mat.
11. Secure the drive bay cover over the drive bays
FIGURE 10-1
(
FIGURE 10-2
).
You must install the drive bay cover over the drive bays to ensure proper airflow in
the system.
10.1.2
Replacing a Cold-Swappable Hard Drive
1. Attach the antistatic wrist strap.
See
Section 1.2, “Attaching the Antistatic Wrist Strap” on page 1-2
.
2. Remove the drive bay cover (
FIGURE 10-1
).
3. Hold the bracket handle on the disk drive open.
4. Slide the replacement disk drive into the drive slot.
5. Gently push the drive until the locking handle engages.
6. Close the locking handle completely, using gentle downward pressure.
7. Replace the drive bay cover.
8. Complete the power-on steps.
See
Section 2.1, “Powering On the Server” on page 2-2
for more information.
9. If you replaced the boot drive, reinstall the Solaris OS.
See the
Netra CT Server Installation Guide
for more information.
10. If the hard drive is under the control of RAID software, perform the necessary
steps to bring the disk online.
Summary of Contents for Netra CT 410
Page 16: ...xvi Netra CT Server Service Manual February 2007...
Page 20: ...xx Netra CT Server Service Manual February 2007...
Page 28: ......
Page 44: ...2 10 Netra CT Server Service Manual February 2007...
Page 48: ...3 4 Netra CT Server Service Manual February 2007...
Page 49: ...PART 2 Troubleshooting the System Troubleshooting the System Chapter 4...
Page 50: ......
Page 88: ......
Page 98: ...5 10 Netra CT Server Service Manual February 2007...
Page 138: ...6 40 Netra CT Server Service Manual February 2007...
Page 154: ...7 16 Netra CT Server Service Manual February 2007...
Page 176: ...8 22 Netra CT Server Service Manual February 2007...
Page 178: ......
Page 198: ...10 10 Netra CT Server Service Manual February 2007...
Page 199: ...PART 5 Illustrated Parts List Illustrated Parts List Chapter 11...
Page 200: ......
Page 208: ...11 8 Netra CT Server Service Manual February 2007...
Page 210: ......
Page 265: ...Appendix A Connector Pinouts A 55...
Page 266: ...A 56 Netra CT Server Service Manual February 2007...
Page 288: ...D 4 Netra CT Server Service Manual February 2007...
Page 296: ...Index 4 Netra CT Server Service Manual February 2007 W web sites third party xxvi...