Appendix C
Error Messages
C-7
Cause
An error occurred when the
scsb
driver received the
retry
command from the
system controller board.
Action
Retry. If the error persists, the system controller board is damaged and should be
replaced. See
Chapter 8
for instructions.
Message
scsb#0: no HEALTHY# signal on slot
#
Cause
You tried to connect or configure a hot-swappable I/O board that was not reporting
itself HEALTHY. The board has failed or was not inserted properly.
Action
Remove the I/O board from the server and reinsert it, making sure the board is
completely and properly inserted into the server. If the error message repeats, then
the board has failed. Replace the I/O board, using the instructions in
Chapter 6
.
Message
scsb#0: Reset Not Asserted on Healthy# Failed slot
#
Summary of Contents for Netra CT 410
Page 16: ...xvi Netra CT Server Service Manual February 2007...
Page 20: ...xx Netra CT Server Service Manual February 2007...
Page 28: ......
Page 44: ...2 10 Netra CT Server Service Manual February 2007...
Page 48: ...3 4 Netra CT Server Service Manual February 2007...
Page 49: ...PART 2 Troubleshooting the System Troubleshooting the System Chapter 4...
Page 50: ......
Page 88: ......
Page 98: ...5 10 Netra CT Server Service Manual February 2007...
Page 138: ...6 40 Netra CT Server Service Manual February 2007...
Page 154: ...7 16 Netra CT Server Service Manual February 2007...
Page 176: ...8 22 Netra CT Server Service Manual February 2007...
Page 178: ......
Page 198: ...10 10 Netra CT Server Service Manual February 2007...
Page 199: ...PART 5 Illustrated Parts List Illustrated Parts List Chapter 11...
Page 200: ......
Page 208: ...11 8 Netra CT Server Service Manual February 2007...
Page 210: ......
Page 265: ...Appendix A Connector Pinouts A 55...
Page 266: ...A 56 Netra CT Server Service Manual February 2007...
Page 288: ...D 4 Netra CT Server Service Manual February 2007...
Page 296: ...Index 4 Netra CT Server Service Manual February 2007 W web sites third party xxvi...