Vista 1 Digital Mixing System
GC Operation 4-135
Document generated: 18.04.17
SW V5.3
4.7.3
Setings: Meter Source Setup
GROUP
1
MAIN
1
GROUP
2
MAIN
2
GROUP
1
EXT
1
GROUP
2
EXT
2
1
2
3
4
5
6
7
8
The master level meter assignment is preconfigured using the Graphical
Controller. Selection of these preconfigured sources will then be done with
the eight hardware
METER
keys below the meter window; these keys have
clip-on caps for inserting individual labels mirroring the individual setting.
The
METER
key numbering 1-8 is shown left.
In order to change metering sources, the operator needs to be logged-on as a
system administrator. This is done in the Settings Ribbon Tab, category Setup.
The
Meter Source
button needs to be pressed.
The Meter Source Setup window opens up and displays all necessary param-
eters to assign metering sources to the six VFD bargraph meters. The steps
below describe the setup process :
Step 1
The desired
METER
source selection key is selected with a click.
Step 2
In the pulldown menu at the right-hand side all sources assignable to the
meters are shown.
Click to select the source, then click on the
<<
arrow button of the desired
bargraph.
Please note that here the numbering is 1 through 6 from top to
bottom, while on the actual desk meters it is 1 through 6 from left to right.
Step 3
Once this is done for all 6 meters, proceed to the next source selection key
Summary of Contents for Vista 1
Page 18: ...Vista 1 Digital Mixing System 1 2 Introduction Document generated 18 04 17 SW V5 3 ...
Page 112: ...Vista 1 Digital Mixing System 2 72 Desk Operation Document generated 18 04 17 SW V5 3 ...
Page 114: ...Vista 1 Digital Mixing System 3 2 Parameters Document generated 18 04 17 SW V5 3 ...
Page 176: ...Vista 1 Digital Mixing System 3 64 Parameters Document generated 18 04 17 SW V5 3 ...
Page 332: ...Vista 1 Digital Mixing System 5 2 D21m Stagebox Handling Document generated 18 04 17 SW V5 3 ...
Page 338: ...Vista 1 Digital Mixing System 6 2 DSP Configurations Document generated 18 04 17 SW V5 3 ...
Page 346: ...Vista 1 Digital Mixing System 7 2 DAW Control Document generated 18 04 17 SW V5 3 ...
Page 356: ...Vista 1 Digital Mixing System 7 12 DAW Control Document generated 18 04 17 SW V5 3 ...
Page 358: ...Vista 1 Digital Mixing System 8 2 RELINK Document generated 14 04 17 SW V5 3 ...
Page 378: ...Vista 1 Digital Mixing System 1 2 Vista 1 FX Document generated 18 04 17 SW V5 3 ...
Page 400: ...Vista 1 Digital Mixing System 1 24 Vista 1 FX Document generated 18 04 17 SW V5 3 ...
Page 401: ...Vista 1 Digital Mixing System Vista FX 1 53 Document generated 18 04 17 SW V5 3 ...