Design and function
Super-Vitesse CFS 3101, 3501 / Super-Vitesse CFS 3101 DO, 3501 DO 10.13
55
5.5
Load-protection bars with integrated automatic charging system
Switch the automatic charging system on for uniform and complete filling of the cargo
space.
The automatic charging system:
●
has to be switched on only once,
●
automatically switches the transport floor on and off during charging,
●
is automatically deactivated if the easy-to-use control set generates an acoustic
signal (horn sound) and a visual signal ("Forage wagon full"),
●
is automatically activated if the forage wagon has been emptied and the pick-up
is lowered the next time,
●
remains switched on until the automatic charging system is manually switched
off.
The automatic charging system only works with the pick-up lowered.
5.5.1
Easy-to-use control of automatic charging system
The automatic charging system:
●
is mounted at the load-protection bars and
mainly consists of the sensing band (1), the
gear shifting gate (2) and the limit
switch (3),
●
is connected with the hydraulic drive of the
transport floor in ON mode,
During charging, the loaded material piles up at
the front panel of the cargo space. If the loaded
material piling up deflects the sensing band (1)
upwards, the hydraulic drive of the transport floor
starts and conveys the loaded material
backwards. The transport floor stops as soon as
the loaded material does not deflect the sensing
band (1) upwards any more.
The position of the gear shifting gate (2) with
respect to the sensing band (1) determines the
switch-on behaviour for the transport floor. The
gear shifting gate (2) can be fixed to the sensing
band (1) in different positions, in order to change
the filling degree of the cargo space.
Low filling degree = smaller deflection of sensing
band
High filling degree = larger deflection of sensing
band
●
Sensing band in upper switch position
→ The automatic charging system is switched
on.
Fig. 23
Auto
1
3
2