Operation
136
Super-Vitesse CFS 3101, 3501 / Super-Vitesse CFS 3101 DO, 3501 DO 10.13
Display (7)
Hydraulic cylinder type
Axle model/Steering/Chassis
BPW
Single-acting
BPW, FAD or forced steering
axle
FAD
Double-acting
FAD
ZWL
Electronic forced steering axle
4. Press the
key once.
The
Working
menu appears.
7.2.4.4 Pre-select filling degree of loaded material in cargo space
The higher the set filling degree, the higher the transport floor feed
rate and the smaller the filling capacity.
1. Press the
and
keys one after
the other.
The
Filling degree
menu appears.
2. Press the
or
key to change
the setting in 5% steps.
The filling degree (1) is changed.
The screen shows:
„Ausladung“ = Filling degree
„Wert ändern“ = Change value
„zurück“ = Backwards
3. Press the
key.
The
Working
menu appears with the
"Automatic charging system on" symbol.
7.2.5
Calibration (ISOBUS control)
7.2.5.1 Calibrate automatic charging system
A calibration of the automatic charging system helps to separately set
the bottom position of the sensing band for switching the transport
floor on and off and the top position of the sensing band to switch
over to maximum feed rate.
Two people are required for calibration of the automatic charging
system. One person moves the sensing band in the cargo space,
while the other person operates the control set on the tractor.