Chapter 3. Configuring the Storage Cabinet
EK–SMCPP–UG. A01
3–5
When you momentarily press the switch you turn off the audible alarm for all
current error conditions in the local subsystem. The alarm remains off until one
of the following conditions occurs:
•
One hour elapses
•
A different fault occurs
•
An existing fault clears and re-occurs
When you press and hold the switch for at least 5 seconds you clear all the fault
codes.
NOTE
The Alarm Control switch does not affect either
the error condition or the error code. Only
correcting the error condition will clear the error
code.
During a controlled power shut down, the Alarm Control switch functions as an
enclosure power switch. When a controlled power shut down isin affect, you
must press the Alarm Control switch to restore dc power to the enclosure.