Chapter 4. Error Analysis and Fault Isolation
EK–SMCPP–UG. A01
4–11
Table 4–4 EMU Fault Code LED Displays (continued)
Display
Error
Error Code 08
Two PVA SCSI ID switch settings are the same.
Corrective Action
Complete first corrective action. If it does not correct the
problem, complete the second.
Ensure PVA SCSI ID settings are set as follows:
– Master Enclosure = 0
– First Expansion Enclosure = 2
– Second Expansion Enclosure = 3
Replace each PVA in sequence until the fault condition
clears.
Error Code 09
EMU installed in PVS slot.
Corrective Action
Install EMU in left slot.
Error Code 0A
No PVA installed.
Corrective Action
Install PVA.
Error Code 0B
Controller fault.
Corrective Action
Requires a controller-specific action.
Error Code 0C
One or more defective power supplies.
Corrective Action
Complete first corrective action. If it does not correct the
problem, complete the second.
Observe all power supply status LEDs.
Replace any power supply with the lower LED OFF.