Chapter 4. Error Analysis and Fault Isolation
EK–SMCPP–UG. A01
4–9
Table 4–4 EMU Fault Code LED Displays
Display
Error
Error Code 01
One of the following error conditions exists:
Boot ROM signature fail.
Boot ROM checksum failure.
Corrective Action
Replace EMU.
Error Code 02
Both microcode images are bad.
Corrective Action
Complete first corrective action. If it does not correct the
problem, complete the second.
Load microcode image to EMU from maintenance
terminal.
Replace EMU.
Error Code 03
Either a PVA SCSI ID switch setting is invalid (4, 5, 6, or
7) or there no master enclosure (SCSI ID 0).
Corrective Action
Complete first corrective action. If it does not correct the
problem, complete the second.
Ensure PVA SCSI ID settings are set as follows:
– Master Enclosure = 0
– First Expansion Enclosure = 2
– Second Expansion Enclosure = 3
Replace each PVA in sequence until the fault condition
clears.