63
TS 700, TS 800
:
Take out the screw (arrow) in the
shutoff valve holder and remove
the shutoff valve.
– Replace the front handle if
necessary.
– Reassemble parts in reverse
376RA358 TG
order.
– Tightening torques,
– Remove shroud,
– Remove the air filter,
– Remove the air filter base,
:
Take out the screw (arrow) from
the bearing (1) on the switch
shaft.
– Remove the bearing.
1
376RA227 TG
:
Pull the switch shaft (1) out of the
left-hand bearing (arrow) and
remove it from the tank housing.
1
376RA228 TG
:
Prise the leaf spring (1) off the
switch shaft with a suitable tool.
If the switch shaft does not remain in
its position, the leaf spring has
become too weak and must be
replaced.
1
376RA229 TG
:
Carefully place the leaf spring (1)
in the fixture on the tank housing.
– Note the installed position.
1
376RA230 TG
11.
Actuating levers
11.1
Switch shaft, stop switch