Reset
Th
is function is used to set the measurement values to zero.
When the speed error status is established, it releases the error.
In the wait to go past reference point status, it releases the status. However, in the wait to go past reference
point status for master calibration, it does not release this status, and a mode error results.
Set
Ethernet
CC-Link
Measurement
mode
This command initiates reset.
Command format
SVZ Designated axis
Return format
Execution results
Target
Designated axis, MG42 hub unit, all axes
Examples of use
Transmission :
SVZ[00A]
(Reset axis A for the MG41 main unit.)
Return
:
OK000
(Successfully
completed.)
Transmission
:
SVZ[03
]
(Reset all the axes for the MG42 hub unit ID03.)
Return
:
OK000
(Successfully
completed.)
Transmission
:
SVZ[
]
(Reset all the axes for the system.)
Return
:
OK000
(Successfully
completed.)
Compatible command
Designated axis RES