![Sony MG40 Series Command Reference Manual Download Page 127](http://html.mh-extra.com/html/sony/mg40-series/mg40-series_command-reference-manual_411003127.webp)
(E)
4-39
MG40 Series
Data transmission protocol
Th
is function is used to set the protocol which is to be used by the data interface.
Set
Setup
mode
Ethernet
The command sets the protocol which is to be used by the data interface.
Command format
NPC=<Value>
<Value>
0 : TCP (Factory setting)
1 : UDP
Return format
Execution results
Target
MG41 main unit
Save setting values
Setting values saved.
Examples of use
Transmission :
NPC=0
Return
:
OK000
Compatible command
None
Acquire
Setup
mode
Ethernet
Measurement
mode
The command acquires the protocol which is used by the data interface.
Command format
NPC?
Return format
NPC=<Value>
<Value>
0 : TCP
1 : UDP
Target
MG41 main unit
Examples of use
Transmission :
NPC?
Return
:
NPC=0
Compatible command
None