![Sony MG40 Series Command Reference Manual Download Page 81](http://html.mh-extra.com/html/sony/mg40-series/mg40-series_command-reference-manual_411003081.webp)
(E)
2-5
MG40 Series
2
Use the CMV command to set the comparator values. (In this example, the comparator values are set
to group number 1.)
CMV[00A]0101=-0.001 CR LF
OK000 CR LF
CMV[00A]0102=0.000 CR LF
OK000 CR LF
CMV[00A]0103=0.001 CR LF
OK000 CR LF
CMV[00A]0104=0.002 CR LF
OK000 CR LF
CMV[01D]0101=0.000 CR LF
OK000 CR LF
CMV[01D]0102=0.002 CR LF
OK000 CR LF
CMV[01D]0103=0.005 CR LF
OK000 CR LF
CMV[01D]0104=0.010 CR LF
OK000 CR LF
3
Use the CMS command to set the comparator setting group number to be used. (In this example, the
comparator group number is set as group number 1.)
CMS[00A]=01 CR LF
OK000 CR LF
CMS[01D]=01 CR LF
OK000 CR LF