RAID problems
• Faulty HDDs should be replaced as soon as possible
as a further HDD failure may result in loss of data.
• The Media RAID HDD is a hot-swappable item.
When the unit is use, do not remove more than one
HDD at a time as removal of a second HDD may
result in loss of data.
Failure or degraded operation of the Media RAID or the
OS RAID may be alerted to an operator in various ways:
• Errors reported on the Diagnostics page of the
Administration web page utility.
• Red LED present on the affected Media RAID drive (to
be visible, the Front Bezel must be removed).
• Performance degradation (frame dropping or slow server
response).
• Failure or degraded operation alert is broadcast to a
nominated client machine using Windows Messenger
(see
HDXC-C030 HDXC-B030 HDXC-X030 HDXC-
L030 Installation Manual
for instructions on setting up
this facility).
Media RAID HDD not present
Caution
Symptom
Possible Problem
Recommended Action
HDD reported as ‘NOT
PRESENT’ or ‘NOT
RECOGNISED’ by the
Administration Web
Pages or 3ware utility
(see
)
during installation
.
Both status LEDs on the
front panel of the HDD
should be off.
If this symptom is
reported
during
normal
operation
, troubleshoot
as for
Poor HDD connector
contact
Ensure HDD is pushed firmly into its slot.
Check HDD status.
Poor S-ATA cable connector
contact
Check S-ATA cable and connections (see
).
Check HDD status.
S-ATA cable fault
Swap S-ATA cables to check whether fault remains.
Check HDD status.
If fault symptom remains with the cable, replace S-ATA cable.
RAID Controller Card fault
If fault persists, confirm symptom by powering off the unit and then
powering the unit checking HDD status using the 3ware BIOS
manager utility (see
“Checking RAID controller BIOS settings” on
).
If RAID setting up problems are present, replace RAID Controller Card
(see
“RAID controller card replacement” on page 89
Poor Backplane Board
connector contact
Check the relevant Backplane Board connections (see
backplane board (PN16-0107)” on page 33
Check HDD status.
Backplane board fault
Swap over HDDs by inserting HDD in another slot position.
Check HDD status.
If the fault symptom remains in the same slot position, replace
Backplane Board (see
“S-ATA backplane replacement” on page 94
).
HDD fault.
If the fault symptom remains with the HDD, replace the faulty HDD
(see
“Media RAID HDD replacement” on page 84
).
Summary of Contents for HDXS-C200
Page 2: ...2 ...
Page 10: ...10 Table of Contents ...
Page 13: ...13 Functional description Chapter 1 Overview ...
Page 68: ...68 PuTTY terminal emulator Chapter 4 Utilities ...
Page 96: ...96 Powered off replacement parts Chapter 6 Parts Replacement ...
Page 101: ...101 Parts location Chapter 8 Spare Parts Parts location 1 2 2 2 2 2 2 2 2 2 2 2 2 ...
Page 102: ...102 Parts location Chapter 8 Spare Parts 101 102 103 104 104 104 104 104 104 104 104 104 ...
Page 104: ...104 Parts location Chapter 8 Spare Parts A B A B 301 302 303 304 305 306 306 306 306 306 ...
Page 105: ...105 ...
Page 106: ...Sony Corporation ...