![Sony HDXS-C200 Service Manual Download Page 59](http://html.mh-extra.com/html/sony/hdxs-c200/hdxs-c200_service-manual_418460059.webp)
59
3ware RAID BIOS manager
Ch
ap
te
r
4
Utili
tie
s
6
Select the first 2 HDDs (ports 0 and 1) by highlighting
the relevant drive and press the
spacebar
.
7
Select
Create Unit
at the bottom of the screen.
8
In the Create Disk Array screen, name the first array
Array0.
9
Set
RAID configuration
as
Mirror (RAID 1)
.
10
Change
StorSave Profile
to
Balanced
and press
OK
11
Repeat steps 7, 8, and 9 above for the remaining drives
to create eight different Mirrored (RAID 1) disk arrays
called:Array0, Array1, Array2, Array3, Array4,
Array5, Array6 and Array7. When complete, the
screen will show all eight disk arrays.
12
Press
F8
to complete the process.
13
A screen is displayed to inform you that all existing
data on these disks will be overwritten. Type
Y
to Save
and Exit.
14
Insert the Pc-Check utility CD and restart the server.
15
Set-up Pc-Check to run diagnostics on the server
hardware (see
).
Summary of Contents for HDXS-C200
Page 2: ...2 ...
Page 10: ...10 Table of Contents ...
Page 13: ...13 Functional description Chapter 1 Overview ...
Page 68: ...68 PuTTY terminal emulator Chapter 4 Utilities ...
Page 96: ...96 Powered off replacement parts Chapter 6 Parts Replacement ...
Page 101: ...101 Parts location Chapter 8 Spare Parts Parts location 1 2 2 2 2 2 2 2 2 2 2 2 2 ...
Page 102: ...102 Parts location Chapter 8 Spare Parts 101 102 103 104 104 104 104 104 104 104 104 104 ...
Page 104: ...104 Parts location Chapter 8 Spare Parts A B A B 301 302 303 304 305 306 306 306 306 306 ...
Page 105: ...105 ...
Page 106: ...Sony Corporation ...