User Manual of A90 Series Inverter
96
3: set torque
4: PID setting
5: output current
F10.08
Proportional factor of
slave reception
0.00-10.00 (multiple)
1.00
●
F10.09 Host sending interval 0.000-30.000
s
0.200
●
F10.56
Options of 485
EEPROM writing
0-10: default operation (for
commissioning)
11: writing not triggered
(available after commissioning)
0
○
F11
User-selected parameter group
F11.00
User-selected
parameter 1
The displayed content is Uxx.xx,
which means that the function
code Fxx.xx is selected. When the
function code F11.00 is enabled,
the keyboard displays U00.00,
indicating that the first selected
parameter is F00.00.
U00.00
●
F11.01
User-selected
parameter 2
U00.01
●
F11.02
User-selected
parameter 3
U00.02
●
F11.03
User-selected
parameter 4
U00.03
●
F11.04
User-selected
parameter 5
U00.04
●
F11.05
User-selected
parameter 6
U00.07
●
F11.06
User-selected
parameter 7
U00.14
●
F11.07
User-selected
parameter 8
U00.15
●
F11.08
User-selected
parameter 9
U00.16
●
F11.09
User-selected
parameter 10
U00.18
●
F11.10
User-selected
parameter 11
U00.19
●
F11.11
User-selected
parameter 12
U00.29
●
F11.12
User-selected
parameter 13
U02.00
●
F11.13
User-selected
parameter 14
U02.01
●
F11.14
User-selected
parameter 15
U02.02
●
F11.15
User-selected
parameter 16
U03.00
●