User Manual of A90 Series Inverter
69
0.1-6,000.0 (rated power of
motor: > 75kW)
F01.11
Leakage inductance of
asynchronous motor
0.01 to 600.00 (rated power of
motor: ≤ 75 kW)
0.001 to 60.000 (rated power of
motor: > 75 kW)
mH
Model
Confirm
○
F01.12
Mutual inductance of
asynchronous motor
0.1 to 6,000.0 (rated power of
motor: ≤ 75 kW)
0.01 to 600.00 (rated power of
motor: > 75 kW)
mH
Model
Confirm
○
F01.13
No-load excitation
current of
asynchronous motor
0.01 to 600.00 (rated power of
motor: ≤ 75 kW)
0.1 to 6,000.0 (rated power of
motor: > 75 kW)
A
Model
Confirm
○
F01.14
Magnetic saturation
coefficient 1 of
asynchronous motor
10.00~100.00
%
87.00
○
F01.15
Magnetic saturation
coefficient 2 of
asynchronous motor
10.00~100.00
%
80.00
○
F01.16
Magnetic saturation
coefficient 3 of
asynchronous motor
10.00~100.00
%
75.00
○
F01.17
Magnetic saturation
coefficient 4 of
asynchronous motor
10.00~100.00
%
72.00
○
F01.18
Magnetic saturation
coefficient 5 of
asynchronous motor
10.00~100.00
%
70.00
○
F01.19
Stator resistance of
synchronous motor
1-60,000 (rated power of motor:
≤75kW)
0.1 to 6,000.0 (rated power of
motor: > 75 kW)
mΩ
Model
Confirm
○
F01.20
d-axis inductance of
synchronous motor
0.01 to 600.00 (rated power of
motor: ≤ 75 kW)
0.001 to 60.000 (rated power of
motor: > 75 kW)
mH
Model
Confirm
○
F01.21
q-axis inductance of
synchronous motor
0.01 to 600.00 (rated power of
motor: ≤ 75 kW)
0.001 to 60.000 (rated power of
motor: > 75 kW)
mH
Model
Confirm
○
F01.22
Counter electromotive
force of synchronous
10.0-2,000.0 (counter
electromotive force of rated
V
Model
Confirm
○