frequency source B
4: switching between main
frequency source A and main and
auxiliary operation results
5: switching between auxiliary
frequency source B and main and
auxiliary operation results
Select the final valid frequency setting channel and operation mode.
F00.06=0: main frequency source A
The final set frequency only depends on the main frequency source A.
F00.06=1: auxiliary frequency source B
The final set frequency only depends on the auxiliary frequency source B.
F00.06=2: main and auxiliary operation results
The final set frequency depends on the main and auxiliary operation results. Refer to
the description of the function code F00.08.
F00.06=3: switching between the main frequency source A and auxiliary
frequency source B
The final set frequency is determined by the status of the input function “26:
Frequency source switching”: invalid, depending on the main frequency source A; valid,
depending on the auxiliary frequency source B.
F00.06=4: switching between main frequency source A and main and auxiliary
calculation results
The final set frequency is determined by the status of the input function “26:
Frequency source switching”: invalid, depending on the main frequency source A; valid,
depending on the main and auxiliary operation results. Refer to the description of the
function code F00.08.
F00.06=5: switching between the auxiliary frequency source B and main and
auxiliary operation results
The final set frequency is determined by the status of the input function “26:
Frequency source switching”: invalid, depending on the auxiliary frequency source B; valid,
depending on the main and auxiliary operation results. Refer to the description of the
function code F00.08.
Function
code
Function code name
Parameter description
Unit
Default
setting
Attribute