User Manual of A90 Series Inverter
109
time
F17.13 VX2 valid delay time 0.000-30.000
s
0.000
●
F17.14
VX2 invalid delay
time
0.000-30.000
s
0.000
●
F17.15 VX3 valid delay time 0.000-30.000
s
0.000
●
F17.16
VX3 invalid delay
time
0.000-30.000
s
0.000
●
F17.17 VX4 valid delay time 0.000-30.000
s
0.000
●
F17.18
VX4 invalid delay
time
0.000-30.000
s
0.000
●
F17.19
VY1 virtual output
function options
The same as the function options
of digital output terminal of F03
group
0
○
F17.20
VY2 virtual output
function options
0
○
F17.21
VY3 virtual output
function options
0
○
F17.22
VY4 virtual output
function options
0
○
F17.23
VY5 virtual output
function options
0
○
F17.24
VY6 virtual output
function options
0
○
F17.25
VY7 virtual output
function options
0
○
F17.26
VY8 virtual output
function options
0
○
F17.27
Virtual output
positive/negative
logic
D7
D6
D5
D4
D3
D2
D1
D0
000
00000
○
VY8 VY7 VY6 VY5 VY4 VY3 VY2 VY1
0: positive logic, valid in the
closed state/invalid in the open
state
1: Negative logic, invalid in the
closed state/valid in the open state
F17.28
Control options of
virtual output
terminal
D7
D6
D5
D4
D3
D2
D1
D0
111
11111
○
VY8 VY7 VY6 VY5 VY4 VY3 VY2 VY1
0: depending on the status of
X1-X7 terminals (VY8: none)
1: depending on the output
function status
F17.29 VY1 valid delay time 0.000-30.000
s
0.000
●