3
02.98
1-51
Siemens AG 1998 All Rights reserved 6SN1197–0AA00 02.98 Edition
SIMODRIVE 611 (PJ)
Assignment of the filter modules to the I/R modules (only
square–wave current operation)
Table 3-16
I/R module
16/21 kW
I/R module
36/47 kW
I/R module
55/71 kW
I/R module
80/104 kW
I/R module
120/156
kW
Filter com-
ponents
Filter module,
16 kW with integral
commutating reac-
tor
Filter module,
36 kW with integral
commutating reac-
tor
Filter module,
55 kW with integral
commutating reac-
tor
Two 55 kW filter mo-
dules with integrated
commutating reactor.
The filter modules are
connected in parallel.
Two 55 kW filter mo-
dules with integrated
commutating reactor.
The filter modules
are connected in pa-
rallel.
Order No.,
Filt. module
6SN1111–
0AA01–0BA1
6SN1111–
0AA01–0CA1
6SN1111–
0AA01–0DA0
2x,
6SN1111–
0AA01–0DA0
2x,
6SN1111–
0AA01–0DA0
Mounting
position
Wall– or floor mounting, refer to dimension drawings, Section 12.
A mounting bracket set is required for floor mounting.
Order No.,
bracket set
for floor
mounting
6SN1162–
0BA06–0AA0
6SN1162–
0BA06–0AA0
6SN1162–
0BA06–0AA0
2,
6SN1162–
0BA06–0AA0
2,
6SN1162–
0BA06–0AA0
Order No.,
heat barrier
for wall
mounting
6SN1162–
0BA07–0AA0
6SN1162–
0BA07–0BA0
6SN1162–
0BA07–0BA0
2,
6SN1162–
0BA07–0BA0
2,
6SN1162–
0BA07–0BA0
Order No.,
heat barrier
for floor
mounting
6SN1162–
0BA07–0AA0
6SN1162–
0BA07–0AA0
6SN1162–
0BA07–0AA0
2,
6SN1162–
0BA07–0AA0
2,
6SN1162–
0BA07–0AA0
Module
width
150 mm
250 mm
300 mm
2 x 300 mm
2 x 300 mm
Filter Filter
26 kg
40 kg
43 kg
2 x 43 kg
2 x 43 kg
I
rated
filter
30 A
67 A
103 A
150 A
225 A
P
v
filter
290 W
460 W
710 W
1220 W
1420 W
Max. con-
nection
cross–sec-
tion
16/10 mm
2 1)
PE,
potential bonding:
M5 thread
50 mm
2
PE,
potential bonding:
M8 thread
50 mm
2
PE,
potential bonding:
M8 thread
2 x 50 mm
2
PE,
potential bonding:
M8 thread
2 x 50 mm
2
PE,
potential bonding:
M8 thread
Terminals,
supply input
L1, L2, L3,
pot. bonding,
shield, PE
L1, L2, L3,
pot. bonding,
shield, PE
L1, L2, L3,
pot. bonding,
shield, PE
2 x L1, L2, L3,
Potential bonding,
screen, PE
2 x L1, L2, L3,
Potential bonding,
screen, PE
Terminals,
output
U, V, W
shield, PE
U, V, W
shield, PE
U, V, W,
shield, PE
2 x U, V, W
shield, PE
2 x U, V, W
shield, PE
I
rated
, fuse
2)
35 A
80 A
125 A
160 A
250 A
Cooling
Non–ventilated
Non–ventilated
Non–ventilated
Non–ventilated
Non–ventilated
Radio inter-
ference
suppression
EN 55011
Cable–borne noise,
limit
value class A
Cable–borne noise,
limit
value class A
Cable–borne noise,
limit
value class A
Cable–borne noise, li-
mit
value class A
Cable–borne noise,
limit
value class A
The filter modules can be mounted horizontally and vertically (line at the bottom,
load at the top).
1) The 1st number is for cable lugs, the 2nd number is valid for finely–stranded conductors without endsleeves.
2) The fuse used must have this rated current. Refer to Table 3-10 for recommended fuses.
Mounting position
of the filter
modules
3.5.1 Assignment of the filter modules to the I/R modules
Summary of Contents for SIMODRIVE 611A
Page 2: ......
Page 6: ......
Page 7: ...SECTION 0 PRELIMINARY INFORMATION 0 7 ...
Page 8: ......
Page 17: ...Section 1 611A Analog Feed Drives 1 17 ...
Page 18: ...1 18 ...
Page 24: ...1 24 ...
Page 39: ...1 39 ...
Page 70: ...1 70 ...
Page 119: ...1 119 ...
Page 120: ......
Page 123: ......
Page 131: ......
Page 158: ...1 158 ...
Page 159: ...1 159 MOUNTING DIMENSIONS ...
Page 160: ...1 160 ...
Page 186: ......
Page 187: ...GENERAL INFORMATION REGARDING AC SERVO MOTORS AL S ...
Page 188: ......
Page 225: ...1FT5 AC SERVO MOTOR DESCRIPTIONS 1FT5 ...
Page 226: ......
Page 321: ...FEEDBACK DEVICES FOR 1FT5 GE ...
Page 322: ......