VS
5.2 Analog outputs
07.94
1-118
Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and Start–Up Guide/IAA/–04.97 Edition
Table 5-9 Reducing the proportional gain with pot. R45 and the influence of pot. R25 on the
parameter board, reduction of Kp in %
Pot. R45
0
1
2
3
4
5
6
7
8
9
10
Potentio
left
33.1
29.5
26.3
23.3
20.4
17.5
14.6
11.5
8.2
4.5
0.1
Potentio-
meter R25
center
90.9
89.4
87.8
85.9
83.7
81
77.5
72.4
64.4
48.7
1.5
meter R25
right
95.1
94.3
93.3
92.3
90.9
89.3
87
83.7
77.9
65
2.8
Table 5-10 Lowest speed before controller and pulse inhibit (braking to n
off
for terminal 64/65
→
pulse cancellation) via potentiometer R1
0
1
2
3
4
5
6
7
8
9
10
n
off
as a %
of n
max
0.34
0.47
0.61
0.74
0.88
1.02
1.15
1.29
1.42
1.56
1.69
Table 5-11 Drift compensation via potentiometer R96 for n
set
= 0
Potentiometer R96
Control range
30 mV
Analog outputs
Function
Terminal
Boundary condition
Speed actual value
Term.75
Non–normalized speed actual value as for
test socket ”X”
Power display
(utilization)
Term.162
j
M/P
j
display (as supplied) Fig. 5–5, display-
j
M/P
j
, Table 5–6, Normalization
Current actual value
Term.162
j
I
act
j
display by changing–over components
(Table 5–8, settings via fixed values)
[
]
n
act
M/P display
I
act
= I
max
t
M display P display
M
P
M
max
P
max
/
Fig. 5-5 M/P
j
display
J
Feed modules (VS)
04.97
Summary of Contents for SIMODRIVE 611A
Page 2: ......
Page 6: ......
Page 7: ...SECTION 0 PRELIMINARY INFORMATION 0 7 ...
Page 8: ......
Page 17: ...Section 1 611A Analog Feed Drives 1 17 ...
Page 18: ...1 18 ...
Page 24: ...1 24 ...
Page 39: ...1 39 ...
Page 70: ...1 70 ...
Page 119: ...1 119 ...
Page 120: ......
Page 123: ......
Page 131: ......
Page 158: ...1 158 ...
Page 159: ...1 159 MOUNTING DIMENSIONS ...
Page 160: ...1 160 ...
Page 186: ......
Page 187: ...GENERAL INFORMATION REGARDING AC SERVO MOTORS AL S ...
Page 188: ......
Page 225: ...1FT5 AC SERVO MOTOR DESCRIPTIONS 1FT5 ...
Page 226: ......
Page 321: ...FEEDBACK DEVICES FOR 1FT5 GE ...
Page 322: ......