02.98
1-35
Siemens AG 1998 All Rights reserved 6SN1197–0AA00 02.98 Edition
SIMODRIVE 611 (PJ)
Interface overview
Note
When using non–PELV circuits, connected at terminals AS1, AS2, termi-
nals 111, 113 and 213, the connector coding must prevent the connector being
incorrectly inserted.
Refer to Catalog NC60.1 for the Order Nos. of the coding plugs.
Only PELV circuits may be connected to terminal 19.
Interface overview NE modules
The interface description is valid for all NE modules with the exception of the UE
module 5/10 kW – this interface has its own description
(refer to p. 1-42).
Table 3-8
Term.
No.
Des.
Function
Type
1)
Typ. voltage/limit values
Max. cross–
section
Terminals avai-
lable in
3)
U1
V1
W1
Supply connection
E
3–ph. 400 V AC
Refer to
Section 4.2
I/R, UE
L1
L2
Contactor supply
I
I
2–ph. 400 V AC, directly from
the supply
L1, L2, L3, refer to Sect. 9.2
16mm
2
/10mm
2 4)
16mm2
/10mm
2 4)
I/R 80/104 kW,
120/156 kW
PE
P600
M600
Protective conductor
DC link
DC link
I
I/O
I/O
0 V
+300 V
–300 V
Bolt
Busbar
Busbar
I/R, UE, monito-
ring module, pul-
sed resistor
Grounding bar
5)
I/O
–300 V
Busbar
I/R, UE
P600
M600
DC link
DC link
I
I
+300 V
–300 V
16mm
2
/10mm
2 4)
16mm
2
/10mm
2 4)
Monitoring
module
1R,
2R,
3R
TR1,
TR2
9)
External resistance
connection
I/O
V300
6mm
2
/4mm
2 4)
Pulsed resistor;
UE 28 kW
X131
Electronics M
I/O
0 V
16mm
2
/10mm
2
4)
I/R, UE. monito-
ring module
1) I = input; O = output; NC = NC contact; NO = NO contact; (for signal, NO = high; NC = low)
2) Terminal 19 is the reference ground (connected inside the module with 10 k
W
to the general reference ground
X131/terminal 15)
It is not permissible that terminal 15 is connected to PE or terminal 19, further, no external voltage sources
may be connected to terminal 15. Terminal 19 may be connected to X131.
3) I/R = Infeed/regenerative feedback module; UE = Uncontrolled infeed; MM = Monitoring module;
PW = Pulse resistor module
4) The 1st number is valid for cable lugs. The 2nd number is valid for finely–stranded conductors
without connector sleeve.
5) The grounding bar is used to ground the DC link M rail through 100 k
Ω
(should preferably be inserted).
6) RESET = Resets the error memory, edge triggered for the complete drive group
(Terminal ”R”
!
Terminal 15 = RESET)
7) Terminals 111-213, positively–driven NC contact (for I/R 16 kW and UE 10 kW, only from Order No.:
6SN114
–1
01–0
)
Terminals 111–113 NO contacts, not positively driven
8) Maximum current load of terminal 9 with respect to 19: 0.5 A.
9) Only for UE 28 kW
3.3.1 Interface overview NE modules
Summary of Contents for SIMODRIVE 611A
Page 2: ......
Page 6: ......
Page 7: ...SECTION 0 PRELIMINARY INFORMATION 0 7 ...
Page 8: ......
Page 17: ...Section 1 611A Analog Feed Drives 1 17 ...
Page 18: ...1 18 ...
Page 24: ...1 24 ...
Page 39: ...1 39 ...
Page 70: ...1 70 ...
Page 119: ...1 119 ...
Page 120: ......
Page 123: ......
Page 131: ......
Page 158: ...1 158 ...
Page 159: ...1 159 MOUNTING DIMENSIONS ...
Page 160: ...1 160 ...
Page 186: ......
Page 187: ...GENERAL INFORMATION REGARDING AC SERVO MOTORS AL S ...
Page 188: ......
Page 225: ...1FT5 AC SERVO MOTOR DESCRIPTIONS 1FT5 ...
Page 226: ......
Page 321: ...FEEDBACK DEVICES FOR 1FT5 GE ...
Page 322: ......