VS
07.94
1-121
Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and Start–Up Guide/IAA/–04.97 Edition
Power–on
Main switch: OFF
Adapt the module to the motor,
standard settings, Section 1
Start–up with battery box
Main switch: ON
Check the motor–PWM inverter connection:
L1, L2, L3 interchanged?
Cable for power connection
Cable for rotor position and tachometer
Briefly enable term.65 (inching)
Open–up the connection between
term.63 and term.9
Yes fault
No
Set 0 V setpoint at the battery box
Main switch: OFF
Enter a low setpoint
(e. g. 0.1 V)
Briefly enable term.65
Yes
Does drive run
continuously ?
No fault
1
Motor
accelerates?
- Connect terminals 48, 63, 64, 663 to terminal 9
- Switch (open) between terminals 65 and 9
Terminals 56/14 at the battery box
Feed modules (VS)
7 Power –on