The following supplementary functions can be set by mounting wired compo-
nents onto the basic board. (from Order No. 6SN1118–0AD11–0AA1 (1 axis)
and from Order No. 6SN1118–0AE11–0AA1 (2 axis) .
Function
BKZ axis 1
BKZ axis 2
Value range
Smoothing, speed controller
C231
C235
0 ... 100nF
Smoothing n
set
C232
C236
0 ... 2.2
m
F
Smoothing n
act
C233
C237
0 ... 100nF
Smoothing n
set
C234
C238
0 ... 100nF
Timer ”speed controller at its endstop”
C239
C240
0 ... 2.2
m
F
Tachometer adaptation
539R, 540R, 541R
R536, R537. R538
0 ...
1
k
W
, 0.1%, 25ppm/k
Clock frequency PBM
R542
R542
62 k
W
...
1
Adaptation range
R543
R544
0 ...
1
k
W
Speed setpoint adaptation
R545
R546
0 ...
1
k
W
Limiting, speed controller I component
R547
R550
100 k
W
... 2 M
W
Electronic weight equalization, pos./neg.
R548/R549
R551/R552
20 k
W
...
1
Response threshold I
2
t monitoring
R553
R554
0 ...
1
k
W
Axial metal film resistors, type of construction 0204 (RM 7.62 mm) and radial
MKT capacitors (RM 5.08 mm) must be located at the positions provided. When
adapting the tachometer, it should be observed that the resistors have a relative
accuracy of 0.1% to one another and a Tk of < 25 ppm/k.
The board could be damaged if the incorrect material is used
Only suitably qualified personnel may carry–out soldering work on the board
(maintaining the ESD Guidelines).
Dimensioning the setting elements (standard interface)
a) Smoothing functions
Speed controller: T=C231(C235)
78 k
W
n
set
:
T=C232(C236)
10 k
W
n
act
: T=C233(C236)
10 k
W
(dependent on the tachometer
potentiometer setting)
I
set
: T=C234(C238)
5 k
W
b) timer, ”speed controller at its endstop”
The monitoring time is 230 ms as standard, and can be increased, when requi-
red, by mounting C239 (C240). The following simple relationship is valid:
C239 (C240)
m
F
T
Zst
=
)
(
+1.15
200 ms
Note
Important
Feed modules (VS)
3.1 Settings elements with standard interface
04.97
Summary of Contents for SIMODRIVE 611A
Page 2: ......
Page 6: ......
Page 7: ...SECTION 0 PRELIMINARY INFORMATION 0 7 ...
Page 8: ......
Page 17: ...Section 1 611A Analog Feed Drives 1 17 ...
Page 18: ...1 18 ...
Page 24: ...1 24 ...
Page 39: ...1 39 ...
Page 70: ...1 70 ...
Page 119: ...1 119 ...
Page 120: ......
Page 123: ......
Page 131: ......
Page 158: ...1 158 ...
Page 159: ...1 159 MOUNTING DIMENSIONS ...
Page 160: ...1 160 ...
Page 186: ......
Page 187: ...GENERAL INFORMATION REGARDING AC SERVO MOTORS AL S ...
Page 188: ......
Page 225: ...1FT5 AC SERVO MOTOR DESCRIPTIONS 1FT5 ...
Page 226: ......
Page 321: ...FEEDBACK DEVICES FOR 1FT5 GE ...
Page 322: ......