Troubleshooting
Table 8-1 Troubleshooting
Fault, user–
friendly interface
Fault, standard
interface
Possible fault cause
1
H1
RMS torque too high? ambient temp.
40
_
C?
2
H2
Actual value cable and shield correctly connected? Motor encoder
defective?
3
H1
Motor overloaded, RMS torque too high?
4
H2
Refer to F2
5
H1
Axis mechanically locked? RMS torque too high?
6
H1
Motor incorrectly connected? External moment of inertia too high?
RMS to high (mechanically locked)?
7
–
Motor feeder interrupted, motor feeder, short–circuit/ground fault
(Vce monitoring stored up to POWER–ON)?
Fault cannot be removed
→
replace module
F
–
5V level faulted
!
replace module
J
Feed modules (VS)
03.96
04.97
8.2 Troubleshooting