3
02.98
1-50
Siemens AG 1998 All Rights reserved 6SN1197–0AA00 02.98 Edition
SIMODRIVE 611 (PJ)
Filter modules and line filter
1)
In order to maintain the EMC Law, the SIMODRIVE 611 system has filter modu-
les and line filters. An essential prerequisite in maintaining the limit values is
that, in addition to the use of filter modules/line filters, the cabinet has been de-
signed and constructed in line with an EMC–correct design. The installation and
connection specifications according to pp.1-54~1-56 must be observed.
These EMC limit values can also be fulfilled using other suitable measures; an
EMC investigation should be made on a case–for–case basis.
Note
When using filter modules (for I/R modules for square–wave current operation),
a separate commutating reactor is not required.
When using an adaptation transformer, this does not mean that the filter mo-
dule or line filter are not required, i.e. the transformer does not replace a filter
module or line filter.
When using filters, which SIEMENS have not released for SIMODRIVE
6SN611, line harmonics and disturbances can occur, which could damage/in-
terfere with other equipment connected to that line supply.
When using line filters (for I/R modules for sinusoidal current operation), the
appropriate HF commutating reactor must be connected in series, refer to
p. 1-46, Connection diagram Fig. 3-13.
Information regarding machines which are located close to one another at diffe-
rent potentials:
Two machines are located close to one another and are connected to the same
distribution through separate cables.
If a SIMODRIVE drive with controlled DC link (I/R module) without filter module
or line filter, is used in one of the two machines, then potential equalization cur-
rents can flow when both machines are connected.
Counter–measure: Directly connect the machines through a short PE cable or
use a filter module/line filter in front of the SIMODRIVE drive.
S
Max. supply voltage 3–ph. 456 V AC, 45...66 Hz
S
may only be used with supplies with grounded neutral point (TN supply net-
works).
When connected to other line supplies, an isolating transformer must be
used.
S
Current de–rating depending on the installation altitude, according to
p.1-29, Fig.3-3.
1)
Filter modules and line filters are not UL/CSA approved.
Operating condi-
tions, filter modu-
les/line filters
3.5 Filter modules and line filter
Summary of Contents for SIMODRIVE 611A
Page 2: ......
Page 6: ......
Page 7: ...SECTION 0 PRELIMINARY INFORMATION 0 7 ...
Page 8: ......
Page 17: ...Section 1 611A Analog Feed Drives 1 17 ...
Page 18: ...1 18 ...
Page 24: ...1 24 ...
Page 39: ...1 39 ...
Page 70: ...1 70 ...
Page 119: ...1 119 ...
Page 120: ......
Page 123: ......
Page 131: ......
Page 158: ...1 158 ...
Page 159: ...1 159 MOUNTING DIMENSIONS ...
Page 160: ...1 160 ...
Page 186: ......
Page 187: ...GENERAL INFORMATION REGARDING AC SERVO MOTORS AL S ...
Page 188: ......
Page 225: ...1FT5 AC SERVO MOTOR DESCRIPTIONS 1FT5 ...
Page 226: ......
Page 321: ...FEEDBACK DEVICES FOR 1FT5 GE ...
Page 322: ......