Step by step
External line settings
46
p
w
Enter the next number for the analog trunk.
or
r
w
Press this key.
Initial status for programming mode.
Reseizure timeout for an external line
There is a timeout for reseizing an external line. Once an
outgoing call has ended the line will remain blocked dur-
ing the specified timeout.
Required:
Programming mode must be activated (*95
31994).
efm
w
Enter the programming code.
di
...
mm
w
Enter the length of time (05 to 99) for the Flash signal,
where 05 = 500 ms (default) to 99 = 9900 ms.
w
Initial status for programming mode.
Maximum time between rings for an
incoming call
This consists of the time interval between two call puls-
es from the local carrier (approximately 6 seconds). At
the end of this time interval, the system disconnects
from the external line and gets ready to receive other
calls.
In some countries the pause between pulses is longer
than 6 seconds. Here you can specify the setting as you
prefer.
Required:
Programming mode must be activated (*95
31994).
When the line is programmed directly, the de-
fault duration of the flash of the line is 240ms
and when the line is programmed with another
PABX system, the default duration of the flash is
100ms.
Valid only for analog trunks.
Summary of Contents for HiPath 1100
Page 1: ...HiPath 1100 HiPath 1120 HiPath 1150 HiPath 1190 Analog MF Telephones Programming Manual ...
Page 111: ...General settings 111 Step by step w Initial status for programming mode ...
Page 199: ...Setup and Installation 199 Required Tools HiPath 1120 Package Contents ...
Page 200: ...Setup and Installation 200 Optional modules 1 2 Version CND ...
Page 201: ...Setup and Installation 201 Setup and Installation 1 2 ...
Page 202: ...Setup and Installation 202 3 4 ...
Page 203: ...Setup and Installation 203 5 6 ...
Page 204: ...Setup and Installation 204 7 Opening the system 8 Removing the Motherboard MB ...
Page 205: ...Setup and Installation 205 9 Lower modules Music EB 200 204 LAN interface and S0 ...
Page 206: ...Setup and Installation 206 Version CND 10 Master and Satellite Modules ...
Page 207: ...Setup and Installation 207 Version CND 11 Upper modules CTR UP0 E UP0 E EVM and EB 200 204 ...
Page 208: ...Setup and Installation 208 Version CND 12 Baby Board VDC module ...
Page 209: ...Setup and Installation 209 Version CND 13 Connections to the Motherboard MB ...
Page 210: ...Setup and Installation 210 Version CND ...
Page 211: ...Setup and Installation 211 14 Connections to the ADSL expansion boards ...
Page 212: ...Setup and Installation 212 Version CND 15 Connections to the UP0 E module ...
Page 213: ...Setup and Installation 213 Version CND 16 Connections to the lower EB 200 204 Music modules ...
Page 214: ...Setup and Installation 214 Version CND 17 Connections to the S0 module ...
Page 216: ...Setup and Installation 216 HiPath 1150 Package Contents ...
Page 217: ...Setup and Installation 217 Setup and Installation 1 2 ...
Page 218: ...Setup and Installation 218 3 Power Supply 4 ...
Page 220: ...Setup and Installation 220 7 CTR UP0 E Module 8 EVM Module ...
Page 221: ...Setup and Installation 221 9 Installing expansion and optional modules 10 ...
Page 222: ...Setup and Installation 222 11 12 Power Supply ...
Page 224: ...Setup and Installation 224 Installing the ADSL TME1 UP0 E and S0 modules 1 2 ...